Validation of Manufacturers Recommended Working Volumes of Fluorochrome-conjugated Monoclonal Antibodies for Flowcytometric Analysis of Lymphocytes
Moses Dabah Lugos, Gwom Irimiya Davou, Tabitha Silas Vem, Venkateswarlu Perikala, Obadiah Dapus Damulak
Asian Hematology Research Journal · pp. 129–141 · Published 8 Jun 2021
Abstract
Background: Flow cytometry is a robust and rapidly growing technique used to analyse multiple parameters concurrently on a single cell basis. Cell populations can be characterised using a combination of both surface and intracellular antigens. The act of generating the best research data under given circumstances begins with a well-designed reagent optimisation protocol. Applying flow cytometric analysis to obtain reliable and dependable research data requires establishing the best working volumes of the monoclonal antibodies. Aim: This study aimed to provide practical illustrations on the approach for determining optimal working volumes (concentrations) of fluorochrome-conjugated monoclonal antibodies for flow cytometry. Methods: Peripheral blood mononuclear cells (PBMCs) from healthy volunteers were stained using three different volumes of respective fluorochrome-conjugated monoclonal antibodies: one volume below, a volume above and the volume recommended by the manufacturers. The antibodies analysed include CD3-FITC, CD4-APC-Cy7, CD19-Alexa Fluor 700, CD45-AmCyan, CD28-PE, and CD45-AmCyan isotype control. Depending on the availability of cells, a total of 10,000 to 30,000 events were acquired for analysis. Combinations of the mean fluorescence intensity (MFI), the number of events in the population of interest, and the clearance of the Isotype control histogram peak from the positive population were used to determine the best working volumes of the mAbs used. Results: The study reported optimum working volumes of 10µL for CD45-Amcyn, 20µL for CD3-FITC, 10µL for CD4-APC-Cy7, 10µL for CD19-Alexa Fluor 700, 20µL for CD28-PE. We confirmed the recommended volumes provided by the manufacturer for CD3-FITC and CD28-PE. However, higher volumes of CD45-Amcyn, CD4-APC-Cy7 and CD19-Alexa Fluor 700 were found more optimal than the recommended volumes supplied by manufacturers. Conclusion: The application of a simple validation experiment for the working volumes (concentrations) of fluorochrome-conjugated monoclonal antibodies, like the one described here, is recommended as an integral part of the optimisation protocol for flow cytometry.
Cited by 0
No indexed citations yet.
Related research
- Phamrmacoligical Therapies for COVID-19: A Comprehensive Review from 2022 Updated Nih, IDSA and ICMR Guidelines — shares topic coverage
- Optimizing the Aggregation Propensity of Therapeutic Monoclonal Antibodies against Cancer and Autoimmune Diseases: A Computational Study — shares topic coverage
- Biopharmaceuticals: New yet Natural — shares topic coverage
- New Monoclonal Antibodies to Human IgA: Obtaining and Study of Biological Properties — shares topic coverage
- Downregulation of Gap Junctions in Astrocytes by Monoclonal Antibodies against the Second Extracellular Loop of Connexin-43 — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.