Performance Assessment of Three Used Glucometers in Côte d'Ivoire: Compliance with ISO 15197 Standards

Hugues Ahiboh, Nehinka P. Minhibo, Joelle A. Koffi, Henri F. Kouakou, Amos Ankotché, Marie-Laure Hauhouot-Attoungbré

Asian Journal of Biochemistry, Genetics and Molecular Biology · pp. 12–24 · Published 28 Aug 2025

10.9734/ajbgmb/2025/v17i9487

Abstract

Background: Self-monitoring of blood glucose is essential for effective diabetes management, necessitating the use of glucometers that maintain precision and accuracy. Environmental factors and prolonged usage may impact their performance. However, there is limited knowledge regarding the analytical performance of these devices after extended periods of use. This study assessed the compliance of three commonly used glucometers in Côte d'Ivoire with ISO 15197 standards. Objective: This study assessed the analytical and diagnostic performance of Accu-Chek Go, Accu-Chek Active, and OneTouch Verio IQ glucometers after prolonged use in tropical settings. Methods: A cross-sectional study was conducted at CeDReS, Treichville University Hospital, Abidjan, from June to December 2023. Capillary blood glucose levels were measured in 100 patients aged 16–84 years using three glucometers. Results were compared with venous blood glucose values obtained via hexokinase/glucose-6-phosphate dehydrogenase enzymatic assay on a Roche Cobas c311 analyzer. Clarke and Parkes error grids assessed diagnostic accuracy, while Bland-Altman plots evaluated analytical precision. Results: Clarke error grid analysis showed diagnostic accuracy above 99%, whereas Parkes consensus grid results were lower. Bland-Altman analysis revealed concordance rates of 91% for Accu-Chek Active, 90% for OneTouch Verio IQ, and 88% for Accu-Chek Go. These rates did not meet the minimum precision standards of 95% as stipulated by ISO 15197: 2013. Conclusion: Despite acceptable diagnostic accuracy, none of the glucometers met ISO 15197 precision standards, emphasizing the need for periodic performance reevaluation to ensure reliable diabetes management in tropical environments.

Blood glucose monitoring glucometer performance diagnostic accuracy analytical precision ISO 15197 Côte d'Ivoire

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.