The Effect of Large Capsulorhexis (>7mm) on the Stability of Refraction Post Cataract Surgery
Journal of Advances in Medicine and Medical Research · pp. 86–93 · Published 9 Jan 2012
10.9734/BJMMR/2012/771Abstract
Purpose: To investigate if the larger capsulorhexis (7mm) is associated with a stable post-operative refraction with Acrysof IQ one-piece IOL (SN60WF, Alcon USA) implantation from 1month to 2 years after cataract surgery. Method: Retrospective chart review was made on 31 eyes of 20 patients. All eyes had uncomplicated phacoemulsification by the author with 7mm capsulorhexis and Acrysof one-piece IOLIQ (SN60WF, Alcon USA) implantation between 4/2007 and 7/2008. IOL Master was used to select the IOL and target refraction was recorded. Refraction data by manifestation in spherical equivalent (SE) at one month, 3 month and 2 years were recorded and input to SPSS19. Result: The mean refractions in spherical equivalent (SE) were statistically significant and excellent positively correlated among the preoperative target refraction (IOL master), one month post-op, three months post-op and two years post-op. P<0.01, Pearson correlation coefficient: r>+0.9 (95%CI 0.91 to 0.98) Conclusion: The 7mm capsulorhexis with Acrysof one-piece IOLIQ (SN60WF, Alcon USA) implanted eyes demonstrated refractive stability from 1 month up to 2 years post operation.
Cited by 0
No indexed citations yet.
Related research
- Phacoemulsification: Awareness among Postoperative Cataract Patients in South East Nigeria — shares topic coverage
- Effect of Anterıor and Posterıor Capsular Polıshıng on the Rate of Posterıor Capsule Opacıfıcatıon — shares topic coverage
- Cataract Surgery in Asian Countries – An Overview — shares topic coverage
- The Effect of Cataract Surgery on the Intraocular Pressure in Eyes with and without Pseudoexfoliation Syndrome — shares topic coverage
- Traumatic Cataract — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.