Skip to content
Research Article Open access CC BY 4.0

Research on Low Voltage Ride through Capability of Offshore Wind Farm Grid Integration Based on Dynamic Reactive Power Compensation

Qilong Wang, Chi Song

Journal of Engineering Research and Reports · pp. 219–229 · Published 5 May 2026

10.9734/jerr/2026/v28i51893

Abstract

The rapid expansion of offshore wind energy and its integration into weak power grids have introduced significant challenges to system stability, particularly under fault conditions that cause voltage sags. Ensuring adequate Low Voltage Ride Through has become essential for maintaining grid reliability and preventing large-scale disconnections of wind farms.To address voltage sags caused by short-circuit faults during the grid integration of large-capacity offshore wind farms via weak networks, this paper establishes a simulation model of a permanent magnet synchronous generator (PMSG)-based offshore wind farm in the PSAT platform. Taking the Critical Clearing Time (CCT) as the core evaluation index, the Low Voltage Ride-Through (LVRT) capability is systematically assessed. By simulating short-circuit disturbances, the transient voltage response at the point of common coupling is analyzed, followed by a comparative evaluation of the voltage support effects of three dynamic reactive power compensation devices: Static Var Compensator (SVC), Static Synchronous Compensator (STATCOM), and Unified Power Flow Controller (UPFC). Results indicate that the rational configuration of dynamic reactive power compensation effectively mitigates voltage drops, significantly extends the CCT, and enhances transient stability margins. The distinct response characteristics and support efficacies of different devices are clarified, providing a theoretical foundation for optimizing LVRT strategies and selecting compensation equipment in offshore wind integration.

Offshore wind farm low voltage ride-through (LVRT) transient voltage stability critical clearing time (CCT) dynamic reactive power compensation

Cited by 1

1 citation reported by external sources — individual citing-article records aren't available to list yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.