Response Surface Methodology Driven Systematic Development of a Stability- indicating RP-UPLC Method for the Quantification of Aliskiren: A Renin Inhibitor
Bikash Ranjan Jena, G. S. N. Koteswara Rao, Rajasekhar Reddy Alavala, Prasanna Kumar Desu, G. Chakravarthi, Suryakanta Swain, Debi Prasad Pradhan, P. Niharika
Journal of Pharmaceutical Research International · pp. 195–211 · Published 2 Dec 2021
10.9734/jpri/2021/v33i52B33617Abstract
Aims: The current study envisages experimental design enabled rapid, sensitive, and stability-indicating RP-UPLC method to quantify Aliskiren in its pharmaceutical formulations. Study Design: Box-Benkhen experimental Design using Response surface methodology. Place and Duration of Study: Department of Analytical Research and Development, Brawn laboratories ltd., Gurugram, India, and Department of Pharmacy KL College Pharmacy, KL Deemed to be University, Vaddesearam, Guntur, Andhra Pradesh, between May 2021 and September 2021. Methodology: The chromatographic partitioning was achieved on a Waters Acuity H class UPLC system, with BEH 130οA, C18 column (100 x 2.1 mm,1.7 μm) having isocratic elution containing (50:50 %v/v) of 0.2% Glacial acetic acid (GAA) : acetonitrile, at constant flow rate using PDA detection. The optimum conditions were delineated, selecting three influential factors (CMPs), i.e., mobile phase composition, flow rate, and injection volume. Systematic optimization was accomplished by 32 Box-Benkhen design using response surface methodology (RSM). Results: The selected variables are evaluated for obtained responses (CAAs), i.e., peak area, retention time (Rt), USP Plate count. The final optimized method employed, organic phase composition 0.2 % GAA (pH 3.0) and acetonitrile 50:50 (% v/v) with 0.3 mL min-1 flow rate. The injection volume was maintained as 2μL with 2 minutes run time and λmax 280 nm. Conclusion: The method was linear for 5-300 ppm, with regression co-efficient (R2) 0.9995. As per ICH guidelines, forced degradation studies were carried out to analyse the stability profile of drug. The short Rt 1.214, minute implies superior robustness, sensitivity, and cost-effectiveness for routine analysis. The results exhibited that RSM approach of QbD will be competently used to optimize the RP-UPLC method with fewer experimental trials and error-free investigation.
Cited by 2
Saleem Javid, K. Ramya, Mohammed Gulzar Ahmed · Bioanalysis · 2025
Aggarapu Susmitha, Galla Rajitha, Gireesh Kumar Eri · Journal of Liquid Chromatography & Related Technologies · 2023
Related research
- Effect of Different Anti-Coagulants on the Accuracy of Glycated Haemoglobin Results — shares topic coverage
- The Use of a Natural Polysaccharide as a Solidifying Agent and Color-Fixing Agent on Modern Paper and Historical Materials — shares topic coverage
- Simple and Selective Determination of Free Chlorine in Aqueous Solutions by an Electrophilic Aromatic Substitution Reaction Followed by Liquid Chromatography Coupled with Mass Spectrometry — shares topic coverage
- Profiling of Disubstituted Chloroacetamides’ Potential Biological Activity by Liquid Chromatography — shares topic coverage
- Synthesis, Purification, Characterization, and ABTS Antioxidant Evaluation of Novel Azo Dyes — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
2
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.