Overcoming Challenges of in Person Prenatal Care: A Pilot Study on the Usability and Acceptability of a Remote Monitoring Device for Pregnant Women in India
Hema Divakar, Richa Mishra, Sheetal Joshi, Bhagyashri Kulkarni, Poorni Narayanan, Rita Singh, Gubbi Venkatasubbaiah Divakar
Asian Research Journal of Gynaecology and Obstetrics · pp. 39–45 · Published 15 Apr 2023
Abstract
Aim: Pregnancies considered high-risk, such as those with gestational diabetes (GDM), require continuous monitoring and special attention to properly manage maternal and fetal parameters. Personalized care is crucial for all pregnant women, particularly those residing in disadvantaged communities, to improve maternal and fetal outcomes. This study evaluated the feasibility and acceptability of the CareMother Fetosense digital, portable device for monitoring non-stress test/cardiotocography (NST/CTG) results remotely, with the aim of reaching the quality care to the last mile. Methodology: Six hospitals in Karnataka were included in this pilot study, and nine doctors were conveniently selected to participate. The doctors were provided with CareMother Fetosense devices to distribute among pregnant women, depending on their individual risk factors and observations. GDM patients in their last trimester (in the last 4-6 weeks of their pregnancy) were instructed to learn to use the device, download the app, and send the report. Total 305 pregnant women were surveyed using a close-ended questionnaire that covered questions about their characteristics, the outcomes of the fetal NST, and the women's perceptions of using the device. A descriptive analysis of the survey data was performed using STATA version 15.1. Results: The majority of the women were primigravida or first-time pregnant (54%), and the remaining 46% were multigravida. A major fraction of the NST results were reactive (89%), indicating that the fetal heart rate responded appropriately to fetal movements during the test. The majority of women diagnosed with GDM reported reactive results (n=37 out of 41). Overall, the women reported finding the usage of the Fetosense device simple, easy, and comfortable, with 99% of them having no issues. Conclusion: This device records fetal heartbeat and uterine contractions and sends real-time alerts to clinicians, allowing for efficient remote monitoring from anywhere. The findings of this study provided a sense of reassurance to pregnant women, and it eliminated the need for repeated visits and unnecessary anxiety. Such advanced healthcare solutions utilizing remote monitoring techniques have the potential to offer substantial cost-saving benefits, alleviate the burden for these women, and increase accessibility to healthcare services.
Cited by 0
No indexed citations yet.
Related research
- Association between Serum Homocysteine Levels and Gestational Diabetes Mellitus — shares topic coverage
- Screening for Gestational Diabetes Mellitus: Findings from a Resource Limited Setting of Nigeria — shares topic coverage
- Evaluation of Triglyceride to High-Density Lipoprotein Cholesterol Ratio and Atherogenic Indices in Gestational Diabetes Mellitus — shares topic coverage
- Nursing Performance in the Care of Gestational Diabetes: An Integrative Literature Review — shares topic coverage
- Serum Vitamin B12 and Folate Status in Gestational Diabetes Mellitus: A Comparative Assessment — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.