Skip to content
Research Article Open access CC BY 4.0

Strength Capacity Characteristics of Welded and Mechanical Couple Spliced Steel Bars for Reinforcing Concrete

Jonathan Sasah, Charles K. Kankam, Jacqueline Obeng, Richard Akuaku, Vincent Akortia, Ernest K. Dapaah

Journal of Engineering Research and Reports · pp. 107–117 · Published 29 May 2026

10.9734/jerr/2026/v28i61916

Abstract

Lapping, the commonest technique used to splice reinforcement bars, needs no special instrument or skill to execute. However, their usage may result in excessive section reinforcement, which may result in a non-ductile response of the spliced region. The structural performance of reinforcement bar splices plays a critical role in ensuring the continuity and load transfer capacity of reinforced concrete members. This study experimentally investigated the tensile behaviour of steel reinforcement bars connected using threaded couplers and welded joints, with particular emphasis on the influence of connection development length and bar diameter. Tensile tests were conducted on 12 mm, 16 mm, and 20 mm diameter reinforcing bars with threaded engagement lengths of d, 3d, and 5d, and weld lengths of end-to-end, 3d, 5d, and 7d. The results show that connection length significantly affects the mechanical performance of both joining techniques. For threaded couplers, the 12 mm bars exhibited substantial reductions in yield and ultimate strengths at short thread engagement (d), achieving only 29–37% of the control strength. However, increasing the thread length to 3d and 5d significantly improved performance, with the 16 mm and 20 mm bars nearly recovering the full strength of the control specimens. In welded connections, increasing the weld length resulted in substantial strength recovery, with welded bars at 5d and 7d achieving strengths comparable to or slightly exceeding those of the control bars. The findings demonstrate that both threaded and welded reinforcement connections can achieve mechanical performance comparable to continuous bars when sufficient connection development length is provided. However, their efficiency varies with bar diameter and connection configuration.

Stress-strain steel reinforcement tension coupler welded joint

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.