Skip to content
Research Article Open access CC BY 4.0

Biomechanical Analysis for Low Lumbar Spine Segment Fusion with Different Cage Locations

Yugang Jiang, Xiongqi Peng, Yu Wang, Cheng Fu, Xiaojiang Sun, Kai Zhang

Current Journal of Applied Science and Technology · pp. 508–519 · Published 6 Jan 2015

10.9734/BJAST/2015/15576

Abstract

Aims: This paper aims to investigate the influence of cage location on the biomechanical behavior of lumbar spine with Transforaminal Lumbar Interbody Fusion (TLIF). Methodology: Firstly, a three-dimensional finite element (FE) model for L4-L5 low lumbar spine segment is established based on computed tomography scan images of a 30-year-old healthy male volunteer. Flexion, extension, lateral bending and torsion motions are simulated and compared with in-vitro cadaveric test data in the literature to validate the lumbar spine FE model. The intact spine model is then modified to TLIF model with one cage insertion under three different implant angles (30°, 45° and 60°). Results: Numerical results show that after fusion treatment the stress increases dramatically, and mainly distributes on cage and pedicle screw-rod system. Though 45° fusion does not have the lowest von Mises stress at the pedicle screw-rod system and the cage, it is still within an allowable strength limit. Besides, 45° fusion has the best balanced stability in four basic physiological motions. So if only one cage uses, the 45° posterior location may be more suitable for L4-L5 interbody fusion than 30° and 60° location. Conclusion: If only one cage uses, the 45° posterior location may be more suitable for L4-L5 interbody fusion than 30° and 60° location.

Biomechanics finite element method lumbar spine fusion cage locations

Cited by 3

NUMERICAL ANALYSIS OF SPINAL LOADS IN SPONDYLOLISTHESIS TREATMENT USING PEDICLE SCREWS – PRELIMINARY RESEARCH

Jarosław ZUBRZYCKI, Natalia SMIDOVA, Jakub LITAK · Applied Computer Science · 2017

Biomechanical analysis of combination Ti/PEEK fusion cage designed with topology optimization

Hongwei Wang, Yi Wan, Xinyu Liu · International Journal of Applied Electromagnetics and Mechanics · 2020

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

3

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.