Skip to content
Research Article Open access CC BY 4.0

Analysis of Radiation Dose Distribution in Nasopharyngeal and Organ Cancer Cases at Risk with Linear Accelerator Radiotherapy 6 MV Photon Energy Using the IMRT Technique at Prof. Hospital. Dr. I. G. N. G. Ngoerah

Safitri Rahmaniyah, Ni Nyoman Ratini, I. Wayan Balik Sudarsana, Ida Bagus Made Suryatika, Komang Ngurah Suarbawa, I. Nengah Artawan, Anak Agung Ngurah Gunawan, Rozi Irhas

Asian Journal of Medicine and Health · pp. 55–61 · Published 18 May 2023

10.9734/ajmah/2023/v21i8838

Abstract

This study aims to determine the distribution of radiation doses on PTV and OAR radioteraphy planning in RSUP. Prof. Dr. I.G.N.G Ngoerah, Bali, Indonesia does no exceed a predetermined limit. The research metode used is the value of Homogenity Index (H), Conformity Index (CI), and the maximum value of radiation ose to the Organ At Risk (OAR), amely the right eye lens, left eye lens, brainstem, optic chiasma, and spinal cord. These data are compared with the provisions of ICRU report 83 and the maximum dose reference value for OAR. Using data from 30 nasopharyngeal cancer patients with a total radiation dose of 7000 cGy. Obtained a value for HI of 0.1214 with a t-test result of 0.459> 0.05 which means it is not significant. While the value for CI is 0.9850 with nonparametric statistical test results of 0.285> 0.05 which means it is not significant. The maximum dose value for the right eye lens is 772.7 cGy with a t-test result of 0.779> 0.05 which means it is not significant. For the maximum value of the dose in the lens of the left eye of 771.0 cGy with a t test result of 0.791> 0.05 which means it is not significant. For the maximum value of the dose in the brain stem of 5178.1 cGy with nonparametric test results of 0.686> 0.05 which means not significant. The maximum dose value at the optic chiasma is 4,837.2 cGy with a nonparametric test result of 0.225>0.05 which means it is not significant. For the maximum value of the dose in the spinal cord of 4,663.3 cGy with a t test result of 0.958> 0.05 which means it is not significant.

Conformity index homogeneity index intensity modulated radiation therapy nasopharyngeal carcinoma organ at risk

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.