Analysis of TE Variations on SNR and CNR Values in Lumbar MRI T2WI Sequences at Bali Mandara Regional General Hospital
Ida Ayu Gede Vidya Pratiwi, Gusti Ngurah Sutapa, Ida Bagus Alit Paramarta, Ida Bagus Made Suryatika, Nyoman Wendri, I Putu Tedy Indrayana, Anak Agung Ngurah Gunawan
Asian Journal of Medicine and Health · pp. 6–11 · Published 23 Jan 2025
10.9734/ajmah/2025/v23i21170Abstract
Aim: This study aims to evaluate the effect of echo time (TE) variation on MRI image quality, which is measured using Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). The focus of the study was on lumbar MRI examinations at RSUD Bali Mandara using a Philips 1.5 Tesla MRI machine. Study Design: This research used an experimental design with a quantitative approach. The study was conducted in the MRI unit at RSUD Bali Mandara from January to October 2024. Methodology: The study involved 30 patients who underwent lumbar MRI examinations. Four TE variations (80 ms, 90 ms, 100 ms, and 110 ms) were applied to analyze SNR and CNR in corpus, discus, and cerebrospinal fluid (CSF) tissues using the ROI (Region of Interest) method. Data were analyzed using IBM SPSS statistical software to evaluate the effect of TE variations on image quality. The MRI machine used was the Philips Achieva 1.5 Tesla with standard lumbar imaging protocol parameters. Results: Increasing the TE value significantly decreased SNR and CNR values. A TE of 80 ms provided the highest SNR and CNR values compared to other TE variations. This indicates that shorter TE produces better image quality. Conclusion: Good MRI image quality is determined by high SNR and CNR values. This study recommends using an 80 ms TE in lumbar MRI imaging protocols to improve the accuracy of clinical interpretations.
Cited by 0
No indexed citations yet.
Related research
- Effect of Slice Thickness Variation on Spatial Resolution of CT-Scan Device Images at the Bali Mandara Hospital Radiology Installation — shares topic coverage
- Effect of Variation Number of Excitation (NEX) Parameter on the Quality Image of Magnetic Resonance Imaging Genu on T2 Weighted Image Sequence at Bali Mandara Regional General Hospital, Indonesia — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.