Analysis of Energy and Cost Performance of Retrofitting Fluorescent Tubes with Compact Fluorescent and Light Emitting Diode Lamps
J. S. Adeleke, A. B. Wahab, E. A. Olanipekun
Journal of Engineering Research and Reports · pp. 34–46 · Published 28 Jul 2020
10.9734/jerr/2020/v14i417133Abstract
Over the years, visual comfort has been described as a major requirement needed to enhance optimal performance of occupants in any learning environment in tertiary institutions. This is reflected in the poor performance of the commonly used Fluorescent Lamps (FL) occasioned by its constant burn-off, high failure rate and reduced durability. Hence, there is a shift to the adoption of Compact Fluorescent Lamp (CFL) and Light Emitting Diode (LED). This study therefore examined the pattern of electricity consumption involving the adoption of FL, CFL and LED in the purposively selected lecture theatres of Obafemi Awolowo University, Ile-Ife, Nigeria. The study was carried out using energy monitor to obtain the consumption data of the lamps for periodic logging at intervals of 1 hr, 3 hrs, 6 hrs, 12 hrs, 1 day, 7 days, 1 month and 3 months respectively; and also to determine the payback period of each of the lamps. From the data collected, patterns of electricity used, electricity savings were calculated and compared to establish performance potentials of each of the lamps. The study found that there was a significant difference in the pattern of electricity consumption of FLs compared with that of CFLs and LEDs, but a reduced margin existed between CFLs and LED lamps. It showed that the FLs consumed 681.576 kWh, 1619.466 kWh and 5652.432 kWh, CFLs consumed 387.302 kWh, 692.479 kWh and 1936.600 kWh, while LED consumed 294.188 kWh, 426.608 kWh and 1499.015 kWh. There were significant differences in consumption with 43, 47 and 65% reduction in electricity consumption using CFLs while 57, 73 and 73% using LED fittings were obtained. The CFLs performed better in terms of return on investments by having a lower payback period when compared to LED. The study concluded that replacing FL with CFL and LED would be desirable option in order to enhance optimal performance of lecture theatres, but in terms of payback period, it would be beneficial to retrofit FLs with CFLs.
Cited by 3
Yujie Lu, Peixian Li, Yih Perng Lee · Journal of Building Engineering · 2021
Jorge Alberto Cárdenas Magaña, Marco Antonio Celis Crisóstomo, Juan M. González López · Sustainability · 2024
Siti Birkha Mohd Ali, M. Hasanuzzaman, N.A. Rahim · Alexandria Engineering Journal · 2021
Related research
- Compliance Test of Percentage Depth Dose (PDD) Using LINAC Machine Brand Electa Precise against American Association of Physicists in Medicine (AAPM) PDD with Electron Beam Energy Variation at Radiotherapy Installation RSUP Prof. Ngoerah in Denpasar — shares topic coverage
- Effect of Dietary Energy and Protein Level and Enzyme Supplementation on Performance and Egg Quality Traits of Laying Hens — shares topic coverage
- Assessment of Biochemical Effect of “Power Horse” Energy Drink on Hepatic, Renal and Histological Functions in Sprague Dawley Rats — shares topic coverage
- Energy Evaluation of Various Compositions of Biomass Waste Briquettes — shares topic coverage
- Effects of Fluidization Velocity and Equivalence Ratio on the Energy and Exergy of the Syngas Produced from Wheat Straw in A Dual-distributor Type Fluidized Bed Gasifier — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
3
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.