Geophysical Evaluation of the Impact of Solid Waste Dumpsite on the Groundwater in Ilokun, Ado-Ekiti, Southwestern Nigeria
A. S. Adeoye, O. O. Ige, A. O. Talabi, A. Oyebamiji
Asian Journal of Geological Research · pp. 93–103 · Published 25 Jul 2023
Abstract
An investigation was carried out at the Ilokun dumpsite in Ado-Ekiti with the intention of converting it into a sanitary landfill. The goal was to determine the potential impact of the liquid waste draining from the dumpsite on the underground water sources. The study utilized the Vertical Electrical Sounding (VES) field technique, which measures the electrical resistivity, with the spacing between half-electrodes (AB/2) ranging from 1 to 65 meters. Three VES stations were set up for data collection, while a control VES point was established outside the dumpsite. The VES data were then quantitatively analyzed through methods such as partial curve matching and computer iteration. The dipole-dipole electrode configuration was also employed to carry out investigation on the dumpsite. The data acquired in this study was inverted using DIPRO software to generate 2-D resistivity structures. The geological layer below VES 1 was recognized as the aquiferous zone, although its remarkably low resistivity of 12 ohm-m was interpreted as an indication of pollution from a conductive contaminant plume. The geoelectric profile beneath VES 1 to 3 revealed the presence of five distinct layers, which are the topsoil, the lateritic sand, the weathered layer, the fresh basement, and the fractured basement. The resistivity and thickness of these layers vary within certain ranges: 61.8–933.6 ohm-m and 0.5–1.5m; 23.5–664.7 ohm-m and 0.6–2.7m; 12–177 ohm-m and 3 –16.9m; and 2356.6–4800.2 and 16.3-33m; and 34.7-146.4 ohm-m respectively. The fractured layer observed in the three VES points is considered the primary aquifer zone. However, the abnormally low resistivity values ranging from 34.7 to 146.4 ohm-m within the fractured layer beneath VES 1 and 3 are believed to be indicative of contamination caused by a conductive plume of pollutants originating from the dumpsite. The 2-D resistivity structures also confirm that the dumpsite is posing a serious threat to the surrounding formations and groundwater especially those located along the east-west direction of the dumpsite. The potential of leachate accumulation is relatively higher along the east-western axis.
Cited by 0
No indexed citations yet.
Related research
- Assessing Groundwater Vulnerability to the Activities of Artisanal Refining in Bolo and Environs, Ogu/Bolo Local Government Area of Rivers State; Nigeria — shares topic coverage
- Geoelectrical Investigation of Basement Complex Areas of Lokoja, North-Central Nigeria — shares topic coverage
- Groundwater Potential Assessment of Iwaro-Oka, SW Nigeria Using Geoelectric Parameters — shares topic coverage
- Challenges Facing the Attainment of the Millennium Development Goals (MDG’s) in the Water Sector: The Niger State Example, Central Nigeria — shares topic coverage
- Hydrogeological Implication of Electrical Resistivity Sounding in Ita-Eku, Ado Ekiti, Nigeria — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.