Functional Prosthetic Valve Dysfunction: An Underrecognized Cause of Elevated Transprosthetic Gradients
Haffane Fadwa, Elaakib Khaoula, Oudadda Soumaya, El Masrioui Joumana, El Karimi Saloua, El Hattaoui Mustapha
Cardiology and Angiology: An International Journal · pp. 67–73 · Published 27 Oct 2026
10.9734/ca/2026/v15i4571Abstract
Background: Elevated transprosthetic gradients are commonly considered a sign of prosthetic valve obstruction. However, certain haemodynamic or physiological conditions may result in increased gradients despite a structurally normal prosthesis. Recognizing these functional abnormalities is essential to avoid misdiagnosis of prosthetic obstruction and inappropriate management. Aims: To assess the frequency and principal clinical, echocardiographic and aetiological characteristics of functional prosthetic valve dysfunction associated with elevated transprosthetic gradients in a single-centre cohort. Methodology: We conducted a retrospective single-centre study at the Department of Cardiology, Mohammed VI University Hospital, Marrakech, including 77 patients with prosthetic valve dysfunction. Clinical, transthoracic and transoesophageal echocardiographic data, together with laboratory data, were analysed. Functional prosthetic valve dysfunction was defined as elevated transprosthetic gradients in the absence of morphological evidence of prosthetic obstruction, with an identified haemodynamic or physiological condition explaining the increased gradients. Results: Functional prosthetic valve dysfunction was identified in 9 of 77 patients (11.7%). The mean age was 55.9 ± 14.3 years, with a female predominance (66.7%). The main underlying conditions were severe anaemia in 4 patients (44.4%), hyperthyroidism in 2 patients (22.2%), patient–prosthesis mismatch in 2 patients (22.2%), and pregnancy in 1 patient (11.1%). All patients were symptomatic, with NYHA functional class II in 3 patients and class III in 6 patients. The mean transprosthetic gradient was 10.3 ± 1.6 mmHg across mitral prostheses and 30.3 ± 7.0 mmHg across aortic prostheses. No definitive morphological evidence of thrombus or pannus was identified in this subgroup. Conclusion: Functional prosthetic valve dysfunction accounted for 11.7% of prosthetic valve dysfunctions in our series. Severe anaemia, hyperthyroidism, patient–prosthesis mismatch, and pregnancy were the main associated conditions. An elevated transprosthetic gradient should therefore not be interpreted in isolation as evidence of prosthetic obstruction. Its assessment should integrate transvalvular flow, Doppler parameters, the clinical context, and prosthetic valve morphology.
Cited by 0
No indexed citations yet.
Related research
- Prognostic Value of NT-proBNP Concentrations in Patients Attending a Hospital Cardiac Service — shares topic coverage
- Assessment of Obstetric Characteristics Associate with Anemia Disease among Pregnant Women Attending Antenatal Clinics at Garowe General Hospital, Somalia — shares topic coverage
- Relationship between Food and Iron Intake and Hemoglobin Levels among Medical Students: A Cross-sectional Study at Indonesian Christian University, Class of 2021 — shares topic coverage
- The Correlation between Anti GAD65 Antibody and Autoimmune Encephalitis with Seizures Responding to IVIG and Rituximab: A Case Report — shares topic coverage
- Understanding Anemia of Odisha: Evidence from National Family Health Surveys — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.