Assessment of Equipment Programming Efficiency for Blood Component Preparation to Enhance Accuracy in Service Settings and Quot
Neha Singh, Bankim Das, Rakesh Kumar, Saurabh Lahare, Shweta Ranjan, Nishith Nayan
Asian Journal of Medical Principles and Clinical Practice · pp. 119–126 · Published 4 Mar 2024
Abstract
Background and Objective: Component preparation is the backbone of blood centre services. Every blood centre follows standard operative techniques, for component preparation and accepts units with match quality uses for patient services. For component preparation units specific equipment named a refrigerated centrifuge machine is used, which works on the principle of centrifugal force and centripetal force. The best programming defined the above quality standard for every separated unit. The objective of the above study is the evaluation of programming of component preparation over centripetal, centrifugal forces acceleration, and deceleration with time intervals. Selection for the best program, which would matches the standard. Materials and Methods: The study was observed over two different highly specialized equipment refrigerated cytocentrifuge machines known as (Rota Silenta and Thremofisher centrifuge), they are programmed for component preparation. Various programming followed by their Acceleration, Deceleration, Mid-interval Time, RPM, RCF, and Gravitational force,(G) were studied. Prepared products (PRBC, FFP, PC and WBC), their quality frequency was checked with a Fully Automated Hematology Analyzer evaluated. Results: HERAEUS CRYOFUGE 16 Centrifuge results outcome was better compared to ROTA SILENTA 630 RS. The best programming of Heraeus croyofuge ACCELERATION (8) mins, DACCELARTION (8) mins and mid-interval (3) mins RPM,2350 and 3450 of 30 cm radius G Computed RCF was 2096 and 4018 noted. The above programming gives the best yield of platelets-287ug/dl, least contamination of FFP of RBC (.01) and platelets (24) ug/dl, prepared PRBC was HCT (69%), RBC was (9.6) ug/dl, and platelets contamination was (186) ug/dl. Among ROTA SILENTA best programmed was Acceleration (8), MID-Interval (3) and Deceleration (4) mins at RPM (2190,3250) with radius ( 29.5) cm along G computed RCF(1342,3018)noted respectively, which gave best product after processing. Conclusion: Section of best programming meets the quality standard and produces the best efficacy in terms of platelets preparation (yield), (hematocrit)-and PRBC preparation. Prepared FFP was less contaminated with RBC and matched with the defined log reduction of WBC. The selection of programming can enhance the quality criteria and meet the above standard product.
Cited by 0
No indexed citations yet.
Related research
- Antipuritive Effect of Aqueous Root Extracts of Moringa oliefera on Alcohol-induced Haematoxicity in Wistar Rats — shares topic coverage
- Fungal Isolation in HIV Patients and CD4 Count — shares topic coverage
- Adverse Haematological Changes in Plasmodium Infected Mice Following Treatment with Azadirachta indica (Neem) Leaf Extract — shares topic coverage
- The Role of Neutrophils, Lymphocytes and Monocytes in Ischemic Heart Disease: Friend or Foe? — shares topic coverage
- Effects of Aloe vera Gel on the Homeopoietic, Biochemical and Histological Parameters and Bone Marrow of Wistar Rats — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.