An Inexpensive Microfluidic PDMS Chip for Visual Detection of Biofilm-forming Bacteria
Rico Kolossa, Assem Abolmaaty, D. M. L. Meyer, Zongqin Zhang
Annual Research & Review in Biology · pp. 1–13 · Published 11 Jan 2018
10.9734/ARRB/2018/37804Abstract
Aims: Design and assembly of an inexpensive microfluidic PDMS chip for visual detection of cell adhesion and biofilm formation. Study Design: Three different styles of microchannels (2.6, 5.0, and 11.5 µl volumes) were designed, fabricated and tested for adhesion and biofilm formation in a microfluidic system. The pressure drop measurements system includes a bio-Ferrograph connected to the PDMS microchannel via a syringe and a pressure transducer. Methodology: Microfluidic chips were fabricated using Polydimethylsiloxane (PDMS) by means of soft lithography. Different cell densities of E.coli K12 cells were introduced to investigate adhesion and biofilm formation at different time intervals. Stabilization time and hydraulic resistance were obtained via a Bio-Ferrograph connected to a pressure transducer. Results: PDMS microfluidic volume (2.6 µl) failed to generate noticeable biofilm, while slight and greatest yield occurred with PDMS microchannels (5.0, and 11.5 µl), respectively, and could detect as low as 26 cells in 11.5 µl microchannel. As incubation time and/or initial cell density increases, cell adhesion increased, illustrated by crystal violet color intensity. High stabilization time (3 h) didn’t allow for bacterial attachment and cultivation inside the microchannel (2.6 µl) while lower stabilization time (10 min) yielded the highest capacity of cell adhesion in microchannel (11.5 µl). Conclusions: We developed a microfluidic chip with low stabilization time and hydraulic resistance, thus offering more volume for adhesion of bacterial cells and biofilm formation. It allowed bacterial cultivation without any addition of nutrients. The microfluidic chip provides a platform to monitor biofilm growth and can be integrated in situ investigations for biological systems, food biotechnology and other industrial biotechnology applications. This would allow a non-destructive and non-invasive monitoring of the biofilm-forming bacteria inside the PDMS microfluidic chip. This work opens opportunities for further investigations of pressure drop phenomena in microchannels that would otherwise go unnoticed in macro scale measurements.
Cited by 1
Ann V. Nguyen, Arash Yahyazadeh Shourabi, Mohammad Yaghoobi · PLOS ONE · 2022
Related research
- Antibacterial Activity of Bidens pilosa Extracts on Escherichia coli O157: H7 Isolated from Apparently Healthy Individuals — shares topic coverage
- Urine Analysis and Determination of Drug Sensitivity Pattern of Isolated Escherichia coli from Urinary Tract Infected Patients — shares topic coverage
- Evaluation of the Effects of Pediococcus acidilactici Isolated from Wara, a Nigerian Milk Product, in the Prevention of Diarrhea and the Modulation of Intestinal Microflora in Wistar Rats — shares topic coverage
- Prevalence, Aetiological Agents and Antimicrobial Resistance Patterns of Urinary Tract Infections among Pregnant Women Attending Mother and Child Hospital, Akure, South-West Nigeria — shares topic coverage
- Molecular Detection of the Arr-2 Gene in Escherichia coli and Klebsiella pneumoniae Resistant to Rifampicin in Abidjan, Côte D'Ivoire — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.