Skip to content
Research Article Open access CC BY 4.0

Comparison of Human Erythrocyte Filterability with Trapping Rate Obtained by Nickel Mesh Filtration Technique: Two Independent Parameters of Erythrocyte Deformability

Takeshi Arita, Mitsuhiro Fukata, Toru Maruyama, Keita Odashiro, Takehiko Fujino, Chizuko Wakana, Aya Sato, Kazue Takahashi, Yoshiko Iida, Shiro Mawatari, Koichi Akashi

International Blood Research & Reviews · pp. 1–8 · Published 22 Oct 2018

10.9734/IBRR/2018/44667

Abstract

Background: Erythrocyte deformability is a major determinant of microcirculation in vivo. Although this concept was defined as filterability evaluated by flow-pressure curve constructed during a filtration process of erythrocyte suspension through a nickel mesh filter, the behaviours of erythrocytes during the filtration process are unknown. Aim: The present study aimed to obtain the better rheological understanding of the behaviours of erythrocytes passing through the nickel mesh filter. Methods: Blood sample was obtained from 8 apparently healthy subjects after obtaining informed consent. Erythrocyte filterability (%) was calculated as the flow rate of a hematocrit-adjusted erythrocyte suspension relative to that of saline at a filtration pressure of 100 mmH2O in flow-pressure curves obtained by nickel mesh filtration technique. Nickel mesh filters showing specific pore sizes of 6.00 μm (step 1) and 5.31 μm (step 2) were chosen, and two-step filtration protocol was performed. Erythrocytes counts (EC) were performed immediately before (ECpre) and after (ECpost) each filtration, and erythrocyte trapping rate (%) was defined as (ECpre – ECpost) / ECpre. Erythrocyte filterability and trapping rate were correlated in each step for data analysis. Results: ECpre was always greater than corresponding ECpost in every subject and in both steps. Erythrocyte filterability in the step 1 (91.8 ± 2.1%) was close to that in the step 2 (90.0 ± 10.3%). Likely, the trapping rate in the step 1 (77.8 ± 2.4%) was close to that in the step 2 (79.4 ± 7.0%). Mean filterability in step 1 did not differ from that in step 2 (p = 0.637), and the same was true with respect to the mean trapping rate (p = 0.516). However, individual comparison between the filterability and the trapping rate of both steps demonstrated no correlation. Conclusions: The present findings indicate that erythrocytes in suspension are trapped substantially by our nickel mesh filter. This trapping rate was not correlated to the erythrocyte filterability obtained by the flow-pressure curve during the nickel mesh filtration. Therefore, the erythrocyte trapping rate should be considered as a hemorheological parameter independent of the erythrocyte filterability.  

Deformability erythrocytes filtration nickel mesh trapping

Cited by 3

3 citations reported by external sources — individual citing-article records aren't available to list yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

3

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.