Determination of pKa and Degradation Products of the Mutated BRAF Inhibitor Vemurafenib and UPLC Assay in Human Urine
Senem Şanli, Ayşe Özdemir, Gülşen Güven, Süleyman Gökçe
Journal of Pharmaceutical Research International · pp. 18–27 · Published 19 Dec 2020
10.9734/jpri/2020/v32i3630986Abstract
In this study, the pKa value of vemurafenib was determined by the dependence of the retention factor on the pH of the mobile phase. The change of pKa in the different acetonitrile fraction ranging between 57.5 and 62.5% (v/v) was studied by using an LC-UV method. Additionally, a simple, reliable, and rapid UPLC method has been developed for the determination of vemurafenib in human urine. Efavirenz was used as an internal standart. For vemurafenib and efavirenz, selectivity factors were found as 1.204. The asymmetry and capacity factors were obtained as 1.100 and 7.532 for vemurafenib. Vemurafenib was exposed to thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were detected by LC/MS/MS method.
Cited by 1
Srinivas Reddy Dannarm, Bharath Reddy Gottimukkula, Choudhary Sampat Dhalaram · Microchemical journal (Print) · 2025
Related research
- A Review on Bioanalytical Method Development and Validation for Estimation of Drugs by Using Hyphenated Techniques and its Applications on Routine Analysis — shares topic coverage
- Sildenafil Determination by Using UPLC in Different Italian Viagra Tablets — shares topic coverage
- Application of Multi-criteria Decision Making Approach and Experimental Design and Development of Stability-indicating UPLC Method for Simultaneous Determination of Losartan Potassium and Hydrochlorothiazide in Bulk and Tablet Dosage Form — shares topic coverage
- Rapid, Simple and Validated Method for Estimation of Zolpidem by UPLC in Tablet Dosage Form — shares topic coverage
- Stability-Indicating RP-UPLC Method Development and Validation for the Process Related Impurities of Nebivolol and Structural Characterization of Its Forced Degradation Products by LC-MS/MS — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
1
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.